BT-1100/560
Blood
orçamento

EXTERIOR - Vertical stainless steel cabinet with 4 swivel castors with 3 "diagonal brakes.
INTERIOR - Stainless steel cabinet equipped with  5 shelves or drawers .
LIGHTING - Led lamps with automatic activation when opening the door and/or optional programmable timer with external access even when the door is closed.
TEMPERATURE HOMOGENIZER - The forced-air circulation ensure perfect homogenization of the temperature at all points inside the equipment. It shuts down when the door is opened.
THERMAL INSULATION - High density injected polyurethane.
DOOR - Triple glass vertical door with anti-fog system, magnetic profile seal with opening alarm.
REFRIGERATION- Through airtight compressor with CFC-free R-134 A ecological gas circulation, forced-air evaporator unit, automatic defrost system with condensate evaporation.
CONTROL PANEL - On the top of the equipment with main switch and protection fuses on the back and membrane-type front panel with soft-touch keys. Electronic microprocessed thermostat with temperature and programming parameters decimal digital display, locking system against inadvertent handling, system that re-establishes the programmed parameters even with abrupt energy variation or equipment shutdown. Filter against electromagnetic noise. Automatic function check system. Equipped with ITTC type sensors. 2.3 amperes battery to support the functions of the electronic panel, to trigger alarms and the dialer on equipment without emergency system.
VISUAL SIGNS - Visual and simultaneous display for commercial power, temperature deviations, open door, power failure and battery charge level. Electronic recorder of maximum and minimum temperatures reached.
AUDIOVISUAL  ALARMS - Temperature below 2 °C, temperature above 8 °C (or 6 °C for storage of blood and its components), or adjustable by user. Alarms for electric power cut, open door, inhibit key to silence the buzzer for 15 minutes, or adjustable by user. Equipped with alarm simulator.
WORKING RANGE - Minimum of 2 °C and maximum of 8 °C (or 6 °C for storage of blood and its components), with set point at 4 ° C, or adjustable by user, with a variation of + -0.1 °C.
TEMPERATURE RECORDER - Electronic recorder of maximum and minimum temperatures reached.
SECURITY SYSTEM - Thermostat installed in parallel with the electronic controller of the equipment, automatically  taking control of compressor functions whenever the electronic control fails.
DIALER - Automatic system that makes telephone calls via  telephone switchboard or direct fixed line for up to six numbers whenever the equipment alarms at critical temperature.
MANAGEMENT SOFTWARE - Real time follow-up,  access to charts and reports remotely via mobile application, including retroactive data, allowing management of the refrigerator via Internet with RS232/485/DB-25 serial output.
OPERATION - Bivolt 127/220 VOLTS 50/60 Hz
WARRANTY - 1 year.

 

OPTIONAL ACCESSORIES

EMERGENCY SYSTEM - It operates through a 12 volts (cc) to 110/220 volts (ac) converter, supporting all the electro-electronic voltages, including the cold compressor, for 24 hours according to the size of equipment. VOLTAGE CONTROLLER - It monitors and activates the Emergency System in the lack or instability of electric power. It emits electrical voltage performance data via data logger and allows real time follow-up by user.

PEN DRIVE - Access to charts and reports from temperature data via pen drive / data logger.

TEMPERATURE CONTROLLER CALIBRATION -  Temperature controller certificate to verify the uncertainty of measurement (IM, errors, trends, etc.), calibrated in three points, + 2 ° C, + 4 ° C and + 6 ° C, traceability proven by INMETRO (RBC).

CELL PHONE AUTOMATIC DIALER - Remote alarm  for locations that are not served by a conventional telephone line, it uses the cellular chip to make automatic calls for up to six numbers (cellular or fixed) whenever the equipment alarms by temperature CRITICAL.

LOCKABLE DOOR - System for door locking and security of stored materials.

ICE BLOCKS KIT - 20 units of recyclable ice capsules to help in temperature maintenance. Only for equipment purchased WITHOUT Emergency System.

SIDE CUSTOMIZED STICKERS

TCP / IP COMMUNICATION INTERFACE - Ethernet communication data converter (internet or intranet). Interface that allows Biotecno devices to connect to networked computers. Through the IP address of the converter it is possible to access and manage the equipment in local network through the Internet.